SIKES

Ver:
Ordenar por:

Control Transformers, Power Isolation transformer DKL 400VA Single Phase

Industrial Control Transformers provide stepped-down voltages to machine tool control devices and meet high inrush industrial applications where electromagnetic components such as relay, solenoids and magnetic motor starters are used.Characteristic of this series:1.Power range: ≤15KVA.2.Phase: single phase3.Primary voltage: 480V/460V/440V/420V/415V/400V/380V/230V/208V/110V4.Secondary volta..

$0,00

DC Choke for 1200V Inverter, Corriente nominal 1200A [Vertical]

Descripción del reactor DC:Los choques de red magnética también se dan cuenta del beneficio bidireccional de los choques de línea. La distorsión del voltaje de línea y las muescas causadas por el variador se filtran del suministro de línea de CA entrante y, a la inversa, la interferencia impuesta en la línea por otros dispositivos se filtra desde el variador. La corriente de cortocircuito disponib..

$0,00

DC Choke for 1200V Inverter, Corriente nominal 970A [Vertical]

Descripción del reactor DC:Los choques de red magnética también se dan cuenta del beneficio bidireccional de los choques de línea. La distorsión del voltaje de línea y las muescas causadas por el variador se filtran del suministro de línea de CA entrante y, a la inversa, la interferencia impuesta en la línea por otros dispositivos se filtra desde el variador. La corriente de cortocircuito disponib..

$0,00

DC Choke for 400V Inverter, Corriente nominal 200A

Descripción de DC Choke:Los choques de red magnética también se dan cuenta del beneficio bidireccional de los choques de línea. La distorsión del voltaje de línea y las muescas causadas por el variador se filtran desde el suministro de línea de CA entrante y, a la inversa, la interferencia impuesta en la línea por otros dispositivos se filtra desde el variador. La corriente de cortocircuito dispon..

$0,00

DC Choke for 400V Inverter, Corriente nominal 210A [Vertical]

Descripción del reactor DC:Los choques de red de la serie DCL también se dan cuenta del beneficio bidireccional de los choques de línea. La distorsión del voltaje de línea y las muescas causadas por el variador se filtran del suministro de línea de CA entrante y, a la inversa, la interferencia impuesta en la línea por otros dispositivos se filtra desde el variador. La corriente de cortocircuito di..

$0,00

DC Choke for 400V Inverter, Corriente nominal 270A [Vertical]

Descripción del reactor DC:Los choques de red de la serie DCL también se dan cuenta del beneficio bidireccional de los choques de línea. La distorsión del voltaje de línea y las muescas causadas por el variador se filtran del suministro de línea de CA entrante y, a la inversa, la interferencia impuesta en la línea por otros dispositivos se filtra desde el variador. La corriente de cortocircuito di..

$0,00

DC Choke for 400V Inverter, Corriente nominal 650A [Vertical]

Descripción del reactor DC:Los choques de red de la serie DCL también se dan cuenta del beneficio bidireccional de los choques de línea. La distorsión del voltaje de línea y las muescas causadas por el variador se filtran del suministro de línea de CA entrante y, a la inversa, la interferencia impuesta en la línea por otros dispositivos se filtra desde el variador. La corriente de cortocircuito di..

$0,00

Dispositivo de generación armónica, banco de carga RCD 150A

Descripción del banco de carga RCD:Sikes RCD Load Bank es un dispositivo de generación de armónicos que proporciona un recurso de armónicos esencial para probar los filtros de armónicos activos para simular la situación de carga sobre la distorsión armónica. Es trifásico y de cuatro cables (incluida la línea de neutro). La carga RD que consta de 3 fases individuales, podría ser una corriente de ar..

$0,00

Dynamic Braking unit heavy load 400V,132-200KW

The HN series was discontinued in 2019,You can choose GN series instead.http://regenerative-drive.sikes-elec.com/Regenerative-drive-and-Braking-Unit/High-end-heavy-load-braking-unitCharacteristic of this series:Rated power: 55KW-400KWRated braking current: ≤400AChopper voltage range: DC660V±5V(Jump line)Voltage grade: 400VMinimum resistance value: 5.0~1.9ΩIP protection: IP00/IP23Terminal:M8ED..

$0,00

Dynamic Braking unit heavy load 400V ,220-280KW

The HN series was discontinued in 2019,You can choose GN series instead.http://regenerative-drive.sikes-elec.com/Regenerative-drive-and-Braking-Unit/High-end-heavy-load-braking-unitCharacteristic of this series:Rated power: 55KW-400KWRated braking current: ≤400AChopper voltage range: DC660V±5V(Jump line)Voltage grade: 400VMinimum resistance value: 5.0~1.9ΩIP protection: IP00/IP23Terminal:M8ED..

$0,00

Dynamic Braking unit heavy load 400V ,315-400KW

The HN series was discontinued in 2019,You can choose GN series instead.http://regenerative-drive.sikes-elec.com/Regenerative-drive-and-Braking-Unit/High-end-heavy-load-braking-unitCharacteristic of this series:Rated power: 55KW-400KWRated braking current: ≤400AChopper voltage range: DC660V±5V(Jump line)Voltage grade: 400VMinimum resistance value: 5.0~1.9ΩIP protection: IP00/IP23Terminal:M8ED..

$0,00

Dynamic Braking unit heavy load 400V ,55-110KW

The HN series was discontinued in 2019,You can choose GN series instead.http://regenerative-drive.sikes-elec.com/Regenerative-drive-and-Braking-Unit/High-end-heavy-load-braking-unitCharacteristic of this series:Rated power: 55KW-400KWRated braking current: ≤400AChopper voltage range: DC660V±5V(Jump line)Voltage grade: 400VMinimum resistance value: 5.0~1.9ΩIP protection: IP00/IP23Terminal:M8ED..

$0,00

Dynamic Braking unit Light-load 100A,75kw

The LN series is to divert the regenerative energy which is produced in the process of decelerating the motor, into a braking unit, converting that energy into heat. Regenerative energy flows from the motor into the inverter DC bus, manifested as increased bus voltage.Characteristic of this series:Rated power: 7.5KW-150KWRated braking current: ≤200AChopper voltage range: DC660V±5V(Jump line)Voltag..

$0,00

Dynamic Braking unit Light-load 150A,110kw

The LN series is to divert the regenerative energy which is produced in the process of decelerating the motor, into a braking unit, converting that energy into heat. Regenerative energy flows from the motor into the inverter DC bus, manifested as increased bus voltage.Characteristic of this series:Rated power: 7.5KW-150KWRated braking current: ≤200AChopper voltage range: DC660V±5V(Jump line)Voltag..

$0,00

Dynamic Braking unit Light-load 200A,132kw

The LN series is to divert the regenerative energy which is produced in the process of decelerating the motor, into a braking unit, converting that energy into heat. Regenerative energy flows from the motor into the inverter DC bus, manifested as increased bus voltage.Characteristic of this series:Rated power: 7.5KW-150KWRated braking current: ≤200AChopper voltage range: DC660V±5V(Jump line)Voltag..

$0,00

Dynamic Braking unit Light-load 50A,30kw

The LN series is to divert the regenerative energy which is produced in the process of decelerating the motor, into a braking unit, converting that energy into heat. Regenerative energy flows from the motor into the inverter DC bus, manifested as increased bus voltage.Characteristic of this series:Rated power: 7.5KW-150KWRated braking current: ≤200AChopper voltage range: DC660V±5V(Jump line)Voltag..

$0,00